TECHNICAL 
          UPDATES 
        New 
          Multi-Flow Features
          
          Knights new Multi-Flow System offers some great features that 
          increase system reliability and ease-of-use for the installer and the 
          operator. The features are:
         
          New Cable Configuration For the Remote Control
           Auto Formula Select (AFS) with Adjustable AFS Signal Time
           System Lockout 
          
        New 
          Cable Configuration
          
        The new 
          Multi-Flow cable configuration provides a male to female extension cable 
          that allows the remote to be removed and reconnected to the female pigtail 
          at the dispenser. This change enables hassle free priming and programming 
          of the system at the dispenser cabinet without the need for special 
          male x male pigtail cables.
        
        
        
        Auto 
          Formula Select
          
        The Auto 
          Formula Select feature will eliminate potential mistakes by the person 
          operating the 
          system. 
        This feature 
          allows the laundry machine to send a signal to the Multi-Flow dispenser, 
          which automatically selects the correct wash formula. The "AFS" 
          signal time is adjustable to designate a time "increment" 
          for 
          selecting formulas.
          The time increments can be set at 1, 2, or 5 seconds. For example, if 
          the AFS signal time is set for 2, a 20 second signal from the washer 
          would choose formula 10.
          
        System 
          Lockout
          
        The System 
          Lockout feature will "lock-out" all incoming supply signals 
          for a period of time after the load count pump receives a load 
          count signal. This will eliminate false signals and signal errors 
          and ensures correct chemical distribution. The lock-out time can be 
          set between 0 to 99 minutes.