TECHNICAL
UPDATES
New
Multi-Flow Features
Knights new Multi-Flow System offers some great features that
increase system reliability and ease-of-use for the installer and the
operator. The features are:
New Cable Configuration For the Remote Control
Auto Formula Select (AFS) with Adjustable AFS Signal Time
System Lockout
New
Cable Configuration
The new
Multi-Flow cable configuration provides a male to female extension cable
that allows the remote to be removed and reconnected to the female pigtail
at the dispenser. This change enables hassle free priming and programming
of the system at the dispenser cabinet without the need for special
male x male pigtail cables.
Auto
Formula Select
The Auto
Formula Select feature will eliminate potential mistakes by the person
operating the
system.
This feature
allows the laundry machine to send a signal to the Multi-Flow dispenser,
which automatically selects the correct wash formula. The "AFS"
signal time is adjustable to designate a time "increment"
for
selecting formulas.
The time increments can be set at 1, 2, or 5 seconds. For example, if
the AFS signal time is set for 2, a 20 second signal from the washer
would choose formula 10.
System
Lockout
The System
Lockout feature will "lock-out" all incoming supply signals
for a period of time after the load count pump receives a load
count signal. This will eliminate false signals and signal errors
and ensures correct chemical distribution. The lock-out time can be
set between 0 to 99 minutes.