TECHNICAL 
          UPDATES
        On-Premise 
          Signal Lockout Feature
          
          The On-Premise, On-Premise Plus, and Multi-Flow, all have a feature 
          that is called Signal Lockout. Signal Lockout can be used to prevent 
          multiple product injections when a supply signal is received several 
          times during a wash cycle. When using the "fill" solenoid 
          as a trigger signal, a solenoid may energize due to low water level 
          in the washer.
          
        The lockout 
          time is selectable and starts counting down when a pump stops running. 
          Any signals received for a pump that has performed its function in that 
          formula will be ignored during the count down period. Any lockout time 
          that may still be counting down when the load count pump activates will 
          be terminated in preparation for the next formula.
          
        The On-Premise 
          lockout time can be selected from 0 to 255 seconds, the On-Premise Plus 
          can be set from 0 to 75 minutes, and the Multi-Flow lockout time is 
          selectable from 0 to 99 minutes.
        The Knight-Trak 
          II has a 5 minute lockout that you can enable or disable. If you still 
          receive multiple injection 
          signals, you can set delay times with no volumes on the second and third 
          levels of your formula.