Search
 

Product Header

ControlGuard FCS

A Concentration Control and Pump System
Engineered Specifically for Chemical Feed Applications

Whether feeding caustic, acid or other conductive liquids to a process, this capable controller does it with ease and accuracy. Compared with other concentration controllers, the ControlGuard FCS is a breeze to program and maintain. Its optional secondary pump and pump controls make it well suited for two point / two chemical injection applications such as eggwash, bottle wash, can wash, and other industrial spray wash applications. ControlGuard FCS can be operated as a probe based dispenser or feed chemicals based on programmed daily/hourly events, repeat cycle
times or discreet signal inputs from PLCs, motor contactors or manual push button.

Key Features:

• Water tight molded plastic case with latch
• Menu driven digital programming
• Password protected menus
• Conductive or inductive probes
• Optional secondary pump controller
• Operates peristaltic, electric or air operated pumps
• Optional low supply beacon
• Private label available
• Temperature compensating inductive probe holds
chemical concentrations constant at any temperature
• Inductive probe never needs cleaning

Get Brochure (Please wait while file opens)
Get Instruction Manual

Download Acrobat Reader


ControlGuard FCS Base Unit


ControlGuard FCS with
500 and 800 Peristaltic Pump


ControlGuard FCS with 800 Peristaltic Pump

ControlGuard FCS with CleanGuard electric diaphragm or FlowGuard air operated pumps.

Inductive Probe or Conductive Probe
 
ControlGuard FCS System
PART # MODEL DESCRIPTION

7165051

CG-FCS

Conductivity Controller Base System (Please specify 110 VAC or 230 VAC)

1600700

N/A

Inductive Probe w/ 25ft. (7.6m) cable and 1/2” NPT thread
7005195 P-120s Conductive Probe w/ Cell Constant 1.0
7224520 KP-8120BDCX Peristaltic 800 Pump Assy (Pump 1) (DC pump) w/ w/ T-66E Squeeze Tube (45 oz/min) (1350 ml/min)
7224519 KP-5200DCX Peristaltic 500 Pump Assy (Pump 2 ) (DC pump) w/ T-50E Squeeze Tube (18 oz/min) (532 ml/min)
0200503 N/A Strobe, Control Guard FCS
1900775 N/A Pump Trigger Switch [for #2 pump: KP 5100 0-100oz/min (250 ml/min)]
7164045   3/8” Air Solenoid Valve, 24 VDC
7140583 KTM-550 Limit Timer to control secondary pump run time w/signal or manual activation (DC Pumps)
7142326 KTM-600 Limit Timer to control secondary pump run time w/signal or manual activation (AC Pumps)
7142218 MT-300 Event Timer w/ 20 Events/Day, One pump output (DC Pumps)
7142228-2 MT-400 Event Timer w/ 20 Events/Day, One pump output (AC pumps)
7140586 CT-550 Repeat Cycle Timer (0-12 min On/ 0-63 Min Off) (DC Pumps)
7141600 CT-600 Repeat Cycle Timer (0-12 min On/ 0-63 Min Off) (AC Pumps)